ARBLACSC_s_SlipAgCtl_FlgAcv
Activation mode for slip angle control at rear axle for curvature control in lateral guidance. 0: No slip angle control 1: Slip angle control active
- Owner
- VMMP_ARB_ARBLACSC
- Group
- Datatype
- Bool
- Safety
- QM
- Unit
- -
- Range
- 0 .. 1
- Source
- VMMP.signal · e55d7161700c3e242e9c676f7245543edec167c9c4876a2b345e20a70684d9f9
- Port type
- MODULE_OUT_RAM
- Shared with
- VMMP_LACC, VMMP_ARB
Raw attributes
{
"lsb": "2^0",
"hash": "35e6f8a6f1bc1ed22175e62b7dbd95d9",
"name": "ARBLACSC_s_SlipAgCtl_FlgAcv",
"unit": "-",
"offset": "0",
"safety": "QM",
"physMax": "1",
"physMin": "0",
"dataType": "Bool",
"portType": "MODULE_OUT_RAM",
"initValue": "0",
"description": "Activation mode for slip angle control at rear axle for curvature control in lateral guidance.\r\n0: No slip angle control\r\n1: Slip angle control active",
"reviewComment": ""
}