Reference data · Step 1
Signals & parameters
Import or choose the authoritative signal and parameter revisions, then import the VME-PROD workbook folder. Existing revisions can be selected during folder import.
Reference versions
2 matching / 2 total versions
| Kind | File | SHA-256 | Records | Active | Action |
|---|---|---|---|---|---|
| Parameter | VMMP.parameter | 0554579bc2cf | 5173 | Active | |
| Signal | VMMP.signal | e55d7161700c | 4368 | Active |
Browse
4368 matching / 4368 active signal definitions. Text search covers name and description, case insensitive.
| Name ↑ | Owner | Class/port | Datatype | Safety | Description |
|---|---|---|---|---|---|
| ARBLLCSC_s_LatCtl_IdxReqIdCur | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Unique ID (identification number) of the currently active LatCtl customer function. |
| ARBLLCSC_s_LatCtl_MdLatCtl | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | ASIL D | EPS control mode for lateral guidance. 0: Lateral guidance not requested 1: Assist1 mode 2: Assist2 mode 3: Park1 mode 4: Park2 mode 5: Pilot mode 6: Assist reduced mode 7: |
| ARBLLCSC_s_LatCtl_StAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Activation mode for lateral guidance. 0: lateral guidance not active 1: lateral control active (LatCtl service) 2: trajectory control active (TrjCtl service) |
| ARBLLCSC_s_LatGuide_IdxSngTrckMdl | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | ASIL D | Customer function specific single track model configuration in LADM: Bit0 = 0: BankingComp Off Bit0 = 1: BankingComp On Bit1 = 0: no global GLPA Override Bit1 = 1: global GLPA |
| ARBLLCSC_s_LgtCtl_BitFldConf | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt16 | ASIL D | Bitfield Configuration for currently active longitudinal guidance (LgtCtl or TrjCtl). |
| ARBLLCSC_s_LgtCtl_DTarLimD | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | Float32 | QM | Currently requested target distance for longitudinal distance limitation (LgtLimD) in the context of longitudinal control (LgtCtl). |
| ARBLLCSC_s_LgtCtl_FlgAcvLimD | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | Bool | QM | Activation Flag for longitudinal stopping distance limitation (LgtLimD) in the context of longitudinal control (LgtCtl). 0: longitudinal distance limitation not active 1: longitu |
| ARBLLCSC_s_LgtCtl_FlgUpdLimD | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | Bool | QM | Update flag for longitudinal stopping distance limitation target value in the context of longitudinal control (LgtCtl). 0: No Update 1: Update |
| ARBLLCSC_s_LgtCtl_IdxAMax | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Allowed acceleration level of currently active LgtCtl/TrjCtl customer function. 0: No limit 1: Driving function limitation characteristic 2: Parking function limitation characte |
| ARBLLCSC_s_LgtCtl_IdxReqIdCur | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | ASIL D | Unique ID (identification number) of the currently active LgtCtl customer function. |
| ARBLLCSC_s_LgtCtl_StAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | ASIL D | Activation mode for longitudinal guidance. 0: longitudinal guidance not active 1: longitudinal acceleration control active (LgtCtl service) 4: trajectory control active (TrjCtl |
| ARBLLCSC_s_LgtCtl_StDeceCritMax | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | ASIL C | Allowed deceleration ASIL-Level (critical deceleration) of currently active LgtCtl/TrjCtl customer function. 0: QM deceleration level 1: ASIL A deceleration level 2: ASIL B dece |
| ARBLLCSC_s_LgtCtlA_ADmd | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | Float32 | ASIL D | Currently active acceleration demand for longitudinal acceleration guidance (LgtCtl). |
| ARBLLCSC_s_LgtCtlA_AGrdMaxDec | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | Float32 | QM | Currently active gradient limit for decreasing acceleration demand for longitudinal acceleration guidance (LgtCtl). |
| ARBLLCSC_s_LgtCtlA_AGrdMaxInc | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | Float32 | QM | Currently active gradient limit for increasing acceleration demand for longitudinal acceleration guidance (LgtCtl). |
| ARBLLCSC_s_LgtDir_StDirReq | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | ASIL B | Currently requested driving direction 0: No request 1: Foward 2: Reverse 3: Neutral |
| ARBLLCSC_s_LgtLatCtl_StReqESCAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | ESC activation request from currently active LgtCtl/LatCtl/TrjCtl customer function. 0: No ESC activation request 1: Overridable activation request 2: Permanent activation reque |
| ARBLLCSC_s_PBTrjCtl_StAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service trajectory control and the service availability for the Customer-Function PB. 0: Off 1: Available 2: NotAvailable 3: Standby 4 |
| ARBLLCSC_s_PHLatCtl_StAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service lateral control and the service availability for the Customer-Function PH. 0: Off 1: Available 2: NotAvailable 3: Standby 4: A |
| ARBLLCSC_s_PHTrjCtl_StAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service trajectory control and the service availability for the Customer-Function PH. 0: Off 1: Available 2: NotAvailable 3: Standby 4 |
| ARBLLCSC_s_TrjCtl_IdxReqIdCur | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Unique ID (identification number) of the currently active TrjCtl customer function. |
| ARBLLCSC_s_TrjCtl_StAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Activation mode for trajectory control guidance. 0: trajectory guidance not active 1: track control active (TrckCtl service) (trajectory control without longitudinal information |
| ARBLLCSC_s_WBATrjCtl_StAcv | VMMP_ARB_ARBLLCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service trajectory control and the service availability for the Customer-Function WBA. 0: Off 1: Available 2: NotAvailable 3: Standby |
| ARBPKCSC_s_ARAPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function ARA. 0: Off 1: Available 2: NotAvailable 3: Standby |
| ARBPKCSC_s_CAAPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function CAA. 0: Off 1: Available 2: NotAvailable 3: Standby |
| ARBPKCSC_s_CAAPrkCtl_StPrkLckAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control lock and the service availability for the Customer-Function CAA. 0: Off 1: Available 2: NotAvailable 3: Standby 4 |
| ARBPKCSC_s_EAPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function EA. 0: Off 1: Available 2: NotAvailable 3: Standby 4 |
| ARBPKCSC_s_EPBPrkCtl_StAlyAcvAut | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function EPB Aut. 0: Off 1: Available 2: NotAvailable 3: Stand |
| ARBPKCSC_s_EPBPrkCtl_StAlyAcvMAR | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function EPB MAR. 0: Off 1: Available 2: NotAvailable 3: Stand |
| ARBPKCSC_s_EPBPrkCtl_StRlsAcvAut | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control release and the service availability for the Customer-Function EPB Aut. 0: Off 1: Available 2: NotAvailable 3: Sta |
| ARBPKCSC_s_EPBPrkCtl_StRlsAcvMAR | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control release and the service availability for the Customer-Function EPB MAR. 0: Off 1: Available 2: NotAvailable 3: Sta |
| ARBPKCSC_s_EPBPrkCtl_StRlsAcvSXR | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control release and the service availability for the Customer-Function EPB SXR. 0: Off 1: Available 2: NotAvailable 3: Sta |
| ARBPKCSC_s_FlgDrvOffReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Activation Flag for Drive-Off-Requests (flank signal). 0: No Request 1: Drive-Off-Request |
| ARBPKCSC_s_FlgPrkAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Flag, for activation prevention of longitudinal, lateral and trajectory control customer functions based on apply status of parking actuators. 0: No activation prevention (Parking |
| ARBPKCSC_s_FlgPrkAcvAly | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Flag, for activation prevention of hold control customer functions based on apply status of parking actuators. 0: No activation prevention (Parking actuators (ParkBrake, ParkPosit |
| ARBPKCSC_s_FlgPrkBrkAlyReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Activation Flag for ParkBrake-Apply-Requests (flank signal). 0: No Request 1: Apply ParkBrake |
| ARBPKCSC_s_FlgPrkBrkLckInfo | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Activation Flag for ParkBrake-Lock-Requests. 0: No Request 1: Lock ParkBrake |
| ARBPKCSC_s_FlgPrkBrkRlsReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Activation Flag for ParkBrake-Release-Requests (flank signal). 0: No Request 1: Release ParkBrake |
| ARBPKCSC_s_FlgPrkLckAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Flag, for activation prevention of longitudinal, lateral and trajectory control customer functions based on lock status of parking actuators and park control apply requests. 0: No |
| ARBPKCSC_s_FlgPrkPosnAlyReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Activation Flag for ParkPosition-Apply-Requests (flank signal). 0: No Request 1: Apply ParkPosition |
| ARBPKCSC_s_FlgPrkPosnLckInfo | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Activation Flag for ParkPosition-Lock-Requests. 0: No Request 1: Lock ParkPosition |
| ARBPKCSC_s_KFGPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function KFG. 0: Off 1: Available 2: NotAvailable 3: Standby |
| ARBPKCSC_s_KFGPrkCtl_StPrkLckAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control lock and the service availability for the Customer-Function KFG. 0: Off 1: Available 2: NotAvailable 3: Standby 4 |
| ARBPKCSC_s_LeavConPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function LeavCon. 0: Off 1: Available 2: NotAvailable 3: Stand |
| ARBPKCSC_s_LeavConPrkCtl_StPrkLckAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control lock and the service availability for the Customer-Function LeaveCon. 0: Off 1: Available 2: NotAvailable 3: Stand |
| ARBPKCSC_s_PBPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function PB. 0: Off 1: Available 2: NotAvailable 3: Standby 4 |
| ARBPKCSC_s_PHPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function PH. 0: Off 1: Available 2: NotAvailable 3: Standby 4 |
| ARBPKCSC_s_PHPrkCtl_StPrkLckAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control lock and the service availability for the Customer-Function PH. 0: Off 1: Available 2: NotAvailable 3: Standby 4: |
| ARBPKCSC_s_PrkAlyCtl_FlgWkReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Flag for Bus wakeup from park control apply service. 0: No Bus wakeup requested 1: Bus wakeup requested |
| ARBPKCSC_s_PrkCtl_StPrkBrkManReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | State of park control requets from customer function EBP MAR. 0: No Request 1: Release Request 2: Apply Request |
| ARBPKCSC_s_PrkLckCtl_FlgWkReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | Bool | QM | Flag for Bus wakeup from park control lock service. 0: No Bus wakeup requested 1: Bus wakeup requested |
| ARBPKCSC_s_RStPrkCtl_StAlyAcv | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Response with actual status of requested service park control apply and the service availability for the Customer-Function RSt. 0: Off 1: Available 2: NotAvailable 3: Standby |
| ARBPKCSC_s_StPrkLckMsgReq | VMMP_ARB_ARBPKCSC | MODULE_OUT_RAM | UInt8 | QM | Lock message of currently active park control lock customer function. Message will be triggered by park control release requests if any park control lock request is active at the s |
| ARBTJCSC_s1_TrjCtl_ADmd | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested demand acceleration at node |
| ARBTJCSC_s1_TrjCtl_AgPosnYaw | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested yaw angle of vehicle (USK coordinate system) for trajectory control |
| ARBTJCSC_s1_TrjCtl_AgSideSlip | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested side slip angle at node |
| ARBTJCSC_s1_TrjCtl_CrvtTrck | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested curvatur at the esquested nodes for trajectory control |
| ARBTJCSC_s1_TrjCtl_DTrck | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | covered distance at requested node for trajectory control |
| ARBTJCSC_s1_TrjCtl_FacIt | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | demanded Factor intensity for the driver for trajectory control |
| ARBTJCSC_s1_TrjCtl_FacSsty | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | demanded Sensitivity of the controller for the driver for trajectory control |
| ARBTJCSC_s1_TrjCtl_LPosnLat | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested y position of vehicle (USK coordinate system) for trajectory control |
| ARBTJCSC_s1_TrjCtl_LPosnLgt | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested x position of vehicle (USK coordinate system) for trajectory control |
| ARBTJCSC_s1_TrjCtl_TiNod | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested time value to reach node for trajectory control |
| ARBTJCSC_s1_TrjCtl_VDmd | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | requested demand velocity at node |
| ARBTJCSC_s_TrjCtl_AgPosnBas | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | yaw angle of vehicle when trajctory is generated (origin of coordinate system is vehicle start) for trajectory control |
| ARBTJCSC_s_TrjCtl_DTlrHi | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | Distance-Tolerance Request after vehicle stopping position for trajectory control |
| ARBTJCSC_s_TrjCtl_DTlrLo | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | Distance-Tolerance Request before vehicle stopping position for trajectory control |
| ARBTJCSC_s_TrjCtl_FlgVldClasCur | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Bool | QM | valid flag for currently operating Trajectory Classfier |
| ARBTJCSC_s_TrjCtl_Id | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | UInt8 | QM | requested counter for the trajctory/path interface for trajectory control |
| ARBTJCSC_s_TrjCtl_IdxStrtPlanNew | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | UInt8 | QM | index of node from which all further nodes are replanned for trajectory control |
| ARBTJCSC_s_TrjCtl_LPosnBasLat | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Int32 | QM | y position of vehicle when trajctory/path ist generated (origin of coordinate system is vehicle start) for trajectory control |
| ARBTJCSC_s_TrjCtl_LPosnBasLgt | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Int32 | QM | x position of vehicle when trajctory/path ist generated (origin of coordinate system is vehicle start) for trajectory control |
| ARBTJCSC_s_TrjCtl_NumNod | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | UInt8 | QM | number of requested nodes for trajectory control |
| ARBTJCSC_s_TrjCtl_StTrjMd | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | UInt8 | QM | the activ Req-ID in TrjCtl |
| ARBTJCSC_s_TrjCtl_TiBas | VMMP_ARB_ARBTJCSC | MODULE_OUT_RAM | Float32 | QM | synchronized time when trajectory is generated for trajectory control |
| ASM_s1_Dyn2Dat | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn2Dat |
| ASM_s1_Dyn3Dat | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn3Dat |
| ASM_s1_Dyn4Dat | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn4Dat |
| ASM_s1_Dyn5Dat | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn4Dat |
| ASM_s1_DynDat | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_DynDat |
| ASM_s1_StatDat | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_StatDat |
| ASM_s_Dyn2_IdEveTyp | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn2_IdEveTyp |
| ASM_s_Dyn3_IdEveTyp | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn3_IdEveTyp |
| ASM_s_Dyn4_IdEveTyp | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn4_IdEveTyp |
| ASM_s_Dyn5_IdEveTyp | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn4_IdEveTyp |
| ASM_s_Dyn_IdEveTyp | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Dyn_IdEveTyp |
| ASM_s_Stat_IdEveTyp | VMMP_SRVPOST_ASM | MODULE_OUT_RAM | UInt8 | QM | ASM_s_Stat_IdEveTyp |
| ASOAF_s_DiagABS_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose ABS |
| ASOAF_s_DiagAIGbxR_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose AIGbxR |
| ASOAF_s_DiagDrvPosn_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose driver position |
| ASOAF_s_DiagEDC_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose EDC |
| ASOAF_s_DiagEDL_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose EDL |
| ASOAF_s_DiagEgyPrfLvl_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for DiagEgyPrfLvl |
| ASOAF_s_DiagEPBActrCtl_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose EPB actuator control |
| ASOAF_s_DiagEPBAlyRls_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose EPB Aly rls |
| ASOAF_s_DiagEPBAlyRlsStActr_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose EPB Aly Rls StActr |
| ASOAF_s_DiagEPBDisp_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose EPB Disp |
| ASOAF_s_DiagESC_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose ESC |
| ASOAF_s_DiagFailSafeStop_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose Failure Safety Stop |
| ASOAF_s_DiagHydBrkAsi_StEveReq | VMMP_SRV_ASOAF | MODULE_OUT_RAM | UInt8 | QM | State event request for Diagnose HydBrkAsi |
Aliases
0 matching / 0 total aliases